FireProtect 2 RB (Heat/Smoke/CO) is a wireless smoke, temperature and carbon monoxide detector. It has a built-in siren for alarm and event notification. It can work as part of the Ajax security system and autonomously without a hub.
The unique smoke chamber does not require regular cleaning, the dual-spectral sensor distinguishes smoke from steam, the thermistor quickly reacts to the burning of synthetic materials, and convenient software minimizes false alarms. All this meets the most modern fire safety standards. The sensor has a well-thought-out design and mounting, which, in combination with the settings in the smartphone, ensures a simple and quick installation.
Key capabilities
Accurate detection of threats
HazeFlow 2 software algorithm to prevent smoke false alarms.
Bispectral optical sensor for filtering false alarms due to smoke.
Smoke chamber that does not require maintenance.
Advanced hardware and software
Synchronous alarm of all fire detectors of the object in 20 seconds.
Built-in siren with a volume of 85 dB at a distance of 3 meters.
Ability to work without an Ajax hub.
Up to 10 years of operation from permanent batteries, and up to 7 years from replaceable ones.
Automatic and manual checking of the smoke chamber
SmartBracket mounting plate with the ability to align the sensor after installation.
Remote control and configuration in Ajax applications.
Adding to Ajax hub via QR code.
Smoke detection
FireProtect 2 detects smoke and does not react to water vapor thanks to a bispectral optical sensor with blue and infrared LEDs. LEDs emit light with different wavelengths, which allows the sensor to determine the size of the volatile particles and respond only to smoke.
The sensor's smoke chamber is protected from dust, dirt and insects. Even if dust enters and settles in the smoke chamber, it does not threaten detection or impair it.The optical system is designed in such a way that non-volatile particles or insects cannot be in two beams at the same time and cause
Detection of a rapid rise in temperature
Two built-in thermistors are responsible for the reaction to temperature rise. Thermistors are located outside the sensor for faster threat detection.
If the room temperature exceeds 64°C or increases by 10°C or more within 1 minute, the sensor recognizes this as a rapid temperature increase and activates an alarm. The temperature alarm can go off even if there is no smoke in the room. This principle of operation gives a significant advantage when burning synthetic materials. After all, during the burning of materials of this type, almost no smoke is released.
Detection of dangerous concentrations of carbon monoxide
A built-in chemical sensor with a service life of at least 10 years is responsible for detecting a dangerous concentration of carbon monoxide in FireProtect 2.
Carbon monoxide (CO) is a colorless, tasteless and odorless gas produced by the incomplete combustion of fuel in automobile engines and heating appliances that run on coal or other natural fuels. For example, it can be formed from fireplaces, boilers, or heating systems. In airtight or closed rooms with poor ventilation, life-threatening concentrations of carbon monoxide can accumulate.
Synchronous alarm of fire detectors
The sensor supports synchronous fire alarms: the function activates the built-in sirens of all Ajax fire sensors in the system if at least one of them is triggered. In the event of a fire, this makes it possible to notify as many people as possible in the facility.
FireProtect 2 sensors have an improved synchronous alarm operation algorithm that allows you to activate the sirens of all fire sensors in 20 seconds.
Work without a hub
FireProtect 2 sensors can be used without connecting to an Ajax hub.In this case, the sensor notifies of fire alarms with a built-in siren and LED indication, but does not send a notification to the user's smartphone, Ajax Translator or PRO Desktop.
Manual and automatic testing
FireProtect 2 regularly checks the status of batteries and built-in sensors. If a malfunction is detected, the hub will instantly send a notification to users and the monitoring console. And the sensor itself will turn on the light and sound notification with the built-in siren and LEDs, respectively. All sensor states can be checked in Ajax applications at any time.
The sensor supports manual testing mode. It is activated by pressing the front panel of the sensor. The front panel has a mechanical button, so it can be pressed either by hand or with a mop. During the test, the built-in siren and sensor testing are triggered. This allows the installation engineer to test the device at any time, as well as to demonstrate to the customer the light and sound indication of the sensor in case of various types of alarms.
Autonomous work
There are two models of FireProtect 2 (Heat / Smoke / CO) - with replaceable and fixed power elements. Sensors with replaceable power cells work for up to 7 years on pre-installed CR123A batteries. After their discharge, the batteries can be replaced with new ones. The model with permanent batteries works for at least 10 years from built-in lithium power cells. After the batteries are discharged, such a sensor must be replaced with a new one.
Quick installation and connection
To install FireProtect 2, it is not necessary to disassemble the sensor housing. Replaceable or non-replaceable power supplies are pre-installed, and the SmartBracket is tool-free to remove from the sensor. The SmartBracket mounting panel has a degree of freedom of 90°. This allows the installation engineer to align the position of the sensor after installation.
The sensor connects to the Ajax security system in less than a minute.Just open the Ajax app, scan the QR code and add the device to the room and security group.
Smoke detection
The sensitive element of the optical bispectral sensor recognizes smoke by the size of particles in the air.
Protection against false alarms does not react to water vapor.
The patented smoke chamber protects the smoke sensor from dust, dirt and insects.
Detection of dangerous temperature
Sensitive element according to the requirements for temperature sensors of class A1.
Alarm due to temperature level at a temperature greater than 64°C.
Alarm due to a sudden increase in temperature when the temperature rises more than 10°C in 1 minute (or sooner).
Carbon monoxide (CO) detection
The sensitive element is a chemical CO sensor
Alarm when the accumulated dose of CO is exceeded
more than 50 ppm (0.005%) - no more than 90 minutes
more than 100 ppm (0.01%) - no more than 40 minutes
more than 300 ppm (0.03%) - no more than 3 minutes
A CO concentration of 400 (0.04%) ppm within 3 hours can be life-threatening. The sensor stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute.
The service life of the sensor is 10 years. After 10 years of operation, the sensor must be replaced with a new one.
Additional features
Synchronous alarm of fire detectors. All fire detectors in the system turn on built-in sirens if at least one of the detectors registers an alarm. A synchronous alarm is activated during one hub-sensor polling interval, but no more than 20 seconds later.
LED indication
green - indication of power
yellow - indication of malfunctions
red - indication of fire alarms
Button on the front panel of the sensor. In normal mode, when pressed, it starts the smoke chamber test.In the event of an alarm or malfunction, pressing turns off the sound notification of the sensor.
Technical characteristics:
Compatibility:
Hubs:
Hub Plus
Hub 2 (2G)
Hub 2 (4G)
Hub 2 Plus
Hub Hybrid (2G)
Hub Hybrid (4G)
Repeaters:
ReX
Rex 2
Jeweler communication technology
Two-way communication.
Device tamper protection.
Block encryption with a floating key.
Instant notifications.
Remote configuration via Ajax application.
Radio frequency ranges: 868.0 – 868.6 MHz
Maximum effective radiated power (ERP): up to 20 mW
Radio range: up to 1700 m (in the absence of interference)
Power supply: 2 CR123A batteries (up to 7 years of autonomous operation)
Dimensions: 124 × 124 × 45 mm
Weight: 273 g
Operating temperature range: from 0°C to +50°C
Permissible humidity: up to 80%
Protection class: IP20
Color: black
Complete set
FireProtect 2 RB (Heat/Smoke/CO) Jeweller
SmartBracket mounting panel
2 CR123A batteries (pre-installed)
Installation kit
Brief instructions
The unique smoke chamber does not require regular cleaning, the dual-spectral sensor distinguishes smoke from steam, the thermistor quickly reacts to the burning of synthetic materials, and convenient software minimizes false alarms. All this meets the most modern fire safety standards. The sensor has a well-thought-out design and mounting, which, in combination with the settings in the smartphone, ensures a simple and quick installation.
Key capabilities
Accurate detection of threats
HazeFlow 2 software algorithm to prevent smoke false alarms.
Bispectral optical sensor for filtering false alarms due to smoke.
Smoke chamber that does not require maintenance.
Advanced hardware and software
Synchronous alarm of all fire detectors of the object in 20 seconds.
Built-in siren with a volume of 85 dB at a distance of 3 meters.
Ability to work without an Ajax hub.
Up to 10 years of operation from permanent batteries, and up to 7 years from replaceable ones.
Automatic and manual checking of the smoke chamber
SmartBracket mounting plate with the ability to align the sensor after installation.
Remote control and configuration in Ajax applications.
Adding to Ajax hub via QR code.
Smoke detection
FireProtect 2 detects smoke and does not react to water vapor thanks to a bispectral optical sensor with blue and infrared LEDs. LEDs emit light with different wavelengths, which allows the sensor to determine the size of the volatile particles and respond only to smoke.
The sensor's smoke chamber is protected from dust, dirt and insects. Even if dust enters and settles in the smoke chamber, it does not threaten detection or impair it.The optical system is designed in such a way that non-volatile particles or insects cannot be in two beams at the same time and cause
Detection of a rapid rise in temperature
Two built-in thermistors are responsible for the reaction to temperature rise. Thermistors are located outside the sensor for faster threat detection.
If the room temperature exceeds 64°C or increases by 10°C or more within 1 minute, the sensor recognizes this as a rapid temperature increase and activates an alarm. The temperature alarm can go off even if there is no smoke in the room. This principle of operation gives a significant advantage when burning synthetic materials. After all, during the burning of materials of this type, almost no smoke is released.
Detection of dangerous concentrations of carbon monoxide
A built-in chemical sensor with a service life of at least 10 years is responsible for detecting a dangerous concentration of carbon monoxide in FireProtect 2.
Carbon monoxide (CO) is a colorless, tasteless and odorless gas produced by the incomplete combustion of fuel in automobile engines and heating appliances that run on coal or other natural fuels. For example, it can be formed from fireplaces, boilers, or heating systems. In airtight or closed rooms with poor ventilation, life-threatening concentrations of carbon monoxide can accumulate.
Synchronous alarm of fire detectors
The sensor supports synchronous fire alarms: the function activates the built-in sirens of all Ajax fire sensors in the system if at least one of them is triggered. In the event of a fire, this makes it possible to notify as many people as possible in the facility.
FireProtect 2 sensors have an improved synchronous alarm operation algorithm that allows you to activate the sirens of all fire sensors in 20 seconds.
Work without a hub
FireProtect 2 sensors can be used without connecting to an Ajax hub.In this case, the sensor notifies of fire alarms with a built-in siren and LED indication, but does not send a notification to the user's smartphone, Ajax Translator or PRO Desktop.
Manual and automatic testing
FireProtect 2 regularly checks the status of batteries and built-in sensors. If a malfunction is detected, the hub will instantly send a notification to users and the monitoring console. And the sensor itself will turn on the light and sound notification with the built-in siren and LEDs, respectively. All sensor states can be checked in Ajax applications at any time.
The sensor supports manual testing mode. It is activated by pressing the front panel of the sensor. The front panel has a mechanical button, so it can be pressed either by hand or with a mop. During the test, the built-in siren and sensor testing are triggered. This allows the installation engineer to test the device at any time, as well as to demonstrate to the customer the light and sound indication of the sensor in case of various types of alarms.
Autonomous work
There are two models of FireProtect 2 (Heat / Smoke / CO) - with replaceable and fixed power elements. Sensors with replaceable power cells work for up to 7 years on pre-installed CR123A batteries. After their discharge, the batteries can be replaced with new ones. The model with permanent batteries works for at least 10 years from built-in lithium power cells. After the batteries are discharged, such a sensor must be replaced with a new one.
Quick installation and connection
To install FireProtect 2, it is not necessary to disassemble the sensor housing. Replaceable or non-replaceable power supplies are pre-installed, and the SmartBracket is tool-free to remove from the sensor. The SmartBracket mounting panel has a degree of freedom of 90°. This allows the installation engineer to align the position of the sensor after installation.
The sensor connects to the Ajax security system in less than a minute.Just open the Ajax app, scan the QR code and add the device to the room and security group.
Smoke detection
The sensitive element of the optical bispectral sensor recognizes smoke by the size of particles in the air.
Protection against false alarms does not react to water vapor.
The patented smoke chamber protects the smoke sensor from dust, dirt and insects.
Detection of dangerous temperature
Sensitive element according to the requirements for temperature sensors of class A1.
Alarm due to temperature level at a temperature greater than 64°C.
Alarm due to a sudden increase in temperature when the temperature rises more than 10°C in 1 minute (or sooner).
Carbon monoxide (CO) detection
The sensitive element is a chemical CO sensor
Alarm when the accumulated dose of CO is exceeded
more than 50 ppm (0.005%) - no more than 90 minutes
more than 100 ppm (0.01%) - no more than 40 minutes
more than 300 ppm (0.03%) - no more than 3 minutes
A CO concentration of 400 (0.04%) ppm within 3 hours can be life-threatening. The sensor stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute.
The service life of the sensor is 10 years. After 10 years of operation, the sensor must be replaced with a new one.
Additional features
Synchronous alarm of fire detectors. All fire detectors in the system turn on built-in sirens if at least one of the detectors registers an alarm. A synchronous alarm is activated during one hub-sensor polling interval, but no more than 20 seconds later.
LED indication
green - indication of power
yellow - indication of malfunctions
red - indication of fire alarms
Button on the front panel of the sensor. In normal mode, when pressed, it starts the smoke chamber test.In the event of an alarm or malfunction, pressing turns off the sound notification of the sensor.
Technical characteristics:
Compatibility:
Hubs:
Hub Plus
Hub 2 (2G)
Hub 2 (4G)
Hub 2 Plus
Hub Hybrid (2G)
Hub Hybrid (4G)
Repeaters:
ReX
Rex 2
Jeweler communication technology
Two-way communication.
Device tamper protection.
Block encryption with a floating key.
Instant notifications.
Remote configuration via Ajax application.
Radio frequency ranges: 868.0 – 868.6 MHz
Maximum effective radiated power (ERP): up to 20 mW
Radio range: up to 1700 m (in the absence of interference)
Power supply: 2 CR123A batteries (up to 7 years of autonomous operation)
Dimensions: 124 × 124 × 45 mm
Weight: 273 g
Operating temperature range: from 0°C to +50°C
Permissible humidity: up to 80%
Protection class: IP20
Color: black
Complete set
FireProtect 2 RB (Heat/Smoke/CO) Jeweller
SmartBracket mounting panel
2 CR123A batteries (pre-installed)
Installation kit
Brief instructions
Characteristics
| Device type | wireless fire detector |
| Product line | Residence Line |
| Installation type | internal, indoors |
| Communication channels | Jeweler communication technology |
| Detection type | smoke detection, carbon monoxide detection, temperature sensor |
| Operating frequency | 868 MHz |
| Power supply | 2 CR123A batteries (installed) |
| Color | black |
| Degree of protection | IP20 |
| Operating temperature, °C | 0 ~ +50 |
| Dimensions, mm | 124 × 124 × 45 |
| Weight, g | 273 |
| Warranty, month | 24 |